Blow-Suction Dust Removal System 30000 m³/h, Automatic pulse-jet – FAON FD-CC300-12L

FAON FD-CC300-12L — 22 kW motor, 30000 m³/h airflow and 0.3 μm filtration. Built for high-bay halls and workpieces too large to enclose.
Features
- Flame-retardant PTFE-coated polyester filter media, 345 m²
- 0.3 μm filtration, ≥99.9% efficiency
- Automatic pulse-jet filter cleaning
- Push-pull airflow loop at operator level
- Nothing sits in the path of a crane or workpiece
FD-CC300-12L — Centralized Dust Collection Systems
A blow-suction dust removal system (push-pull) for large, high-bay workshops. Supply and extract ductwork form a directed airflow loop at operator level, capturing fume without obstructing production.
The cartridge gives 345 m² of flame-retardant coated media, filtering to 0.3 μm at ≥99.9% @ 0.3 μm. Cleaning is automatic pulse-jet, so differential pressure stays stable across a full shift without stopping the line.
The 22 kW fan runs on 380 V / 50 Hz and moves 30000 m³/h, holding noise at 75±3 dBA. Overall dimensions are 2500×1380×3400 mm and the unit weighs 1300±30 kg.
Key features
- Push-pull design for large fabrications where weld positions move and fume is hard to capture
- Airflow and pressure CFD analysis with multi-branch balancing for even suction at every hood
- VFD control adjusts fan speed to local dust concentration, cutting energy use
- IoT smart platform — remote control, unmanned operation, fault warning and plant-wide predictive maintenance
- Mobile app for live monitoring, remote parameter tuning and one-touch start/stop
Technical specifications
| Model | FD-CC300-12L |
|---|---|
| Motor Power | 22 kW |
| Working Voltage | 380 V / 50 Hz |
| Air Volume | 30000 m³/h |
| Filtration Efficiency | ≥99.9% @ 0.3 μm |
| Filter Material | Imported flame-retardant PTFE-coated polyester |
| Filter Area | 345 m² |
| Cleaning Mode | Automatic pulse-jet |
| Noise Level | 75±3 dBA |
| Dimensions | 2500×1380×3400 mm |
| Weight | 1300±30 kg |
Typical applications
Large fabrication halls where weld positions move, oversized workpieces, and halls where conventional capture hoods cannot reach the fume source.
Product pictures