Features

  • Flame-retardant PTFE-coated polyester filter media, 80 m²
  • 0.3 μm filtration, ≥99.9% efficiency
  • Automatic rotary-wing reverse-pulse (compressed air 0.5–0.6 MPa) filter cleaning
  • Three-side enclosure contains the work zone
  • Spark trap protects the cartridge from hot particles

FD-GB100-16S-EX — Downdraft Tables & Grinding Booths

A downdraft table (grinding cabinet) for grinding dust extraction, with a three-side enclosure, replaceable work surface and automatic reverse-pulse cleaning that keeps airborne dust contained.

The 16 cartridges give 80 m² of flame-retardant coated media, filtering to 0.3 μm at ≥99.9% @ 0.3 μm. Cleaning is automatic rotary-wing reverse-pulse (compressed air 0.5–0.6 mpa), so differential pressure stays stable across a full shift without stopping the line.

The 3 kW × 2 fan runs on 380 V / 50 Hz and moves 5000–10000 m³/h, holding noise at ≤75 dBA. Overall dimensions are 2100×1030×2285 mm and the unit weighs 600±20 kg. The explosion-protection package covers the motor, control cabinet, conductive cartridges and venting path — certified accessories are quoted against your dust data.

Key features

  • One-piece cabinet with premium sheet-metal construction — rigid, compact, impact & scratch resistant
  • Three-side enclosed / downdraught-and-upward-return internal air circuit keeps dust fully contained, no secondary dust clouds
  • Replaceable work-surface panels suit frames, enclosures and tubular parts
  • Explosion-proof lighting (aluminium housing, explosion-proof glass, cool flicker-free light)
  • Automatic rotary-wing pulse reverse-jet / mechanical rapping with slide-out dust drawer

Technical specifications

ModelFD-GB100-16S-EX
Motor Power3 kW × 2
Working Voltage380 V / 50 Hz
Air Volume5000–10000 m³/h
Filtering Accuracy0.3 μm
Filtration Efficiency≥99.9% @ 0.3 μm
Filter MaterialImported flame-retardant PTFE-coated polyester
Filter Area80 m²
Filter Cartridges16 cartridges (3230)
Cleaning ModeAutomatic rotary-wing reverse-pulse (compressed air 0.5–0.6 MPa)
Noise Level≤75 dBA
Dimensions2100×1030×2285 mm
Weight600±20 kg

Typical applications

Grinding, linishing, deburring, sanding and cut-off operations on frames, enclosures, tubes and castings; machine-shop, silicon-material and foundry fettling dust.

Product pictures

  • When does a grinding job need the explosion proof FD-GB100-16S-EX booth?

    When the dust is combustible — aluminium, magnesium, titanium or coated composites — and the operation generates sparks. The booth gives a 2100 x 1030 mm enclosed working face with 5000-10000 m3/h of extraction through 80 m2 of anti-static media.

  • What does the Ex build add to a standard grinding booth?

    Ex-rated 3 kW fans and control cabinet, conductive anti-static cartridges bonded to earth, a spark arrestor at the inlet and flameless venting on the plenum. Send us the Kst, Pmax and MIE of your dust and we confirm the vent area and the interlock logic.

  • Sixteen cartridges and 80 m2 — how does that handle heavy grinding dust?

    It is deliberately generous: at 10000 m3/h the face velocity is low, so pressure drop stays stable and the 16 cartridges last 12-18 months even on continuous aluminium grinding. Pulse-jet cleaning is automatic on differential pressure.

  • What footprint and services does a 600 kg booth need?

    2100 x 1030 mm of floor, 2285 mm height and 600 kg, plus a level slab and 1 m of clearance at the cartridge side. The booth is normally placed against a wall with the working face toward the operator, and the vent path must discharge away from walkways.

  • Two 3 kW Ex fans — what supply and protection?

    380 V / 50 Hz, 6 kW total, so a 25 A curve-D breaker with 6 mm2 conductors and an earth bond to the booth frame. Noise is ≤75 dBA outside the booth; the Ex rating covers the motor, terminal box and control cabinet, and the earth continuity is tested at commissioning.

Need help selecting?