Industrial Welding Fume Extractor 4500–6000 m³/h, Automatic pulse-jet – FAON FD-CC60-4N

FAON FD-CC60-4N industrial fume & dust extractor — view 1

FAON FD-CC60-4N — 4 kW motor, 4500–6000 m³/h airflow and 0.3 μm filtration. Built for welding, plasma and laser cutting fume, grinding dust and process dust.

Features

  • Nano flame-retardant cartridge filter media, 92 m²
  • 0.3 μm filtration, ≥99.9% efficiency
  • Automatic pulse-jet filter cleaning
  • Recirculates clean air — no roof duct, no heat loss
  • Hood, arm or trolley matched to the capture point

FD-CC60-4N — Industrial Fume & Dust Extractors

A cabinet-style industrial welding fume extractor for welding, cutting and grinding stations. Filtered air can be recirculated indoors, avoiding the heat loss that comes with ducted extraction.

The 4 cartridges give 92 m² of flame-retardant coated media, filtering to 0.3 μm at ≥99.9% @ 0.3 μm. Cleaning is automatic pulse-jet, so differential pressure stays stable across a full shift without stopping the line.

The 4 kW fan runs on 380 V / 50 Hz and moves 4500–6000 m³/h, holding noise at 75±3 dBA. Overall dimensions are 1240×1375×2410 mm and the unit weighs 760 kg.

Key features

  • Integrated cabinet design with compact footprint and mobile chassis
  • Multiple capture options — dust hood, φ160–φ200 external-skeleton extraction arm, dust trolley
  • Imported flame-retardant coated polyester / nano cartridges, 0.3 μm
  • Fully automatic pulse-jet cleaning, optional rotary-wing reverse-pulse
  • Intelligent control panel with remote linkage, auto cleaning and filter-status monitoring

Technical specifications

ModelFD-CC60-4N
Motor Power4 kW
Working Voltage380 V / 50 Hz
Air Volume4500–6000 m³/h
Filtration Efficiency≥99.9% @ 0.3 μm
Filter MaterialImported nano flame-retardant cartridge
Filter Area92 m²
Cleaning ModeAutomatic pulse-jet
Noise Level75±3 dBA
Dimensions1240×1375×2410 mm
Weight760 kg

Typical applications

Welding fume, plasma and laser cutting fume, grinding and polishing dust, aluminium dust and mixing / dosing dust across fabrication, steelwork, automotive and general engineering.

Product pictures

  • How many welding stations can the 6000 m3/h FD-CC60-4N support?

    Four to six stations on a trunked system: 4500-6000 m3/h with 4 kW gives roughly 1000 m3/h per station, which is the right allowance for fume arms of 3 m to 4 m. Beyond six stations the duct losses need the 10500 m3/h FD-CC100-8N.

  • 92 m2 across 4 cartridges — how does that change the service interval?

    It roughly triples the dust holding capacity of a single-cartridge cabinet, so at the same loading the FD-CC60-4N runs 18-24 months between cartridge changes instead of 12. Pulse-jet cleaning is automatic on pressure drop, and all four cartridges come out through one side access panel.

  • What does a 760 kg, 2410 mm tall collector need under it?

    A level floor capable of 760 kg plus the duct load, 1240 x 1375 mm of clear footprint and 1.5 m in front for cartridge removal. Height is 2410 mm, so allow 2.7 m to the ceiling for the outlet collar and a 90-degree elbow.

  • Does the 4 kW fan need a soft starter on a 380 V supply?

    Not normally — 4 kW direct-on-line is fine on a 380 V / 50 Hz supply with a 16 A curve-D breaker, provided the site does not have a tight voltage-dip limit. Noise stays at 75±3 dBA, so the unit can sit inside the bay rather than in a plant room.

  • Can the FD-CC60-4N be expanded later if the line grows?

    Treat it as a fixed-capacity unit: the 4 kW fan and 92 m2 of media are matched, so adding stations means adding a second collector or replacing with the FD-CC100-8N. What you can extend cheaply is the ductwork, as long as total static stays under 1500 Pa.

Need help selecting?

Send us your workshop layout, dust or fume type and airflow target — our engineers will size the right unit, including ductwork and multi-station systems, and return a selection drawing.